This article is intended for service technicians and experienced troubleshooters. Basic causes such as a completely dead battery or loose battery cables are covered in the standard Error Code 1505 guide.

If the starter cranks but the engine does not start..

The controller is not detecting an RPM signal from the magnetos.

Step 1.

Backprobe the bullet connector that connects wire 18 from the controller to the ignition coils. On most units this is located near the oil filter.

Step 2.

Set your meter for AC voltage and attempt to crank the engine. You are looking for 3-6 VAC on V-Twin engines and 1-3 VAC on single cylinder engines.

If your readings are outside of those ranges, disconnect the bullet connector and test from the end coming from the ignition coils to ground as you crank the engine.

If you are now measuring correct voltage, the issue is either with wire 18 going to the controller, or the controller itself.

If you are still not seeing correct voltage, the issue is likely with your ignition coils.

If the starter does not crank..

Step 1.

Check battery voltage. If not over 12.5 VDC, replace the battery and retest. Sidenote: Does the controller go blank or reset when attempting to crank? This is a good sign the battery is bad, there is impedance through the battery cables or there is a bad ground.

Step 2.

Disconnect the two red wires going to the starter contactor relay. On most units these are wires 13 and 16.

starter contactor relay diagram showing location of wires 13 and 16.

Step 3.

Use a jumper to jump them together. By doing this, you are bypassing the controller and the relay, jumping battery voltage directly to the starter.

If the starter cranks by jumping 13 and 16 together:

  1. Disconnect wire 56 from the starter contactor relay. This is usually a blue wire.
  2. Measure from wire 56 to ground as you attempt to crank the engine. You are looking for battery voltage.
  3. If no voltage is measured, this is the issue. Check continuity through wire 56 from the relay end to the controller. If the wire tests good, replace the controller.
  4. If voltage is measured on wire 56 when trying to crank, replace the relay.

If the starter still does not crank by jumping 13 and 16 together:

  1. Measure battery voltage. A good battery should not drop below 10 VDC. If it does replace or charge the battery and retest.
  2. Grab both the battery cables and wiggle them. If by doing this, the starter cranks, replace the battery cables.
  3. If the starter doesn’t crank by wiggling the battery cables, replace the starter.